Abstract

BACKGROUND In patients with diabetes, hospitalization can complicate the achievement of recommended glycemic targets. There is increasing evidence that a closed-loop delivery system (artificial pancreas) can improve glucose control in patients with type 1 diabetes. We wanted to investigate whether a closed-loop system could also improve glycemic control in patients with type 2 diabetes who were receiving noncritical care.

METHODS In this randomized, open-label trial conducted on general wards in two tertiary hospitals located in the United Kingdom and Switzerland, we assigned 136 adults with type 2 diabetes who required subcutaneous insulin therapy to receive either closedloop insulin delivery (70 patients) or conventional subcutaneous insulin therapy, according to local clinical practice (66 patients). The primary end point was the percentage of time that the sensor glucose measurement was within the target range of 100 to 180 mg per deciliter (5.6 to 10.0 mmol per liter) for up to 15 days or until hospital discharge.

RESULTS The mean (±SD) percentage of time that the sensor glucose measurement was in the target range was 65.8±16.8% in the closed-loop group and 41.5±16.9% in the control group, a difference of 24.3±2.9 percentage points (95% confidence interval [CI], 18.6 to 30.0; P<0.001); values above the target range were found in 23.6±16.6% and 49.5±22.8% of the patients, respectively, a difference of 25.9±3.4 percentage points (95% CI, 19.2 to 32.7; P<0.001). The mean glucose level was 154 mg per deciliter (8.5 mmol per liter) in the closed-loop group and 188 mg per deciliter (10.4 mmol per liter) in the control group (P<0.001). There was no significant between-group difference in the duration of hypoglycemia (as defined by a sensor glucose measurement of <54 mg per deciliter; P = 0.80) or in the amount of insulin that was delivered (median dose, 44.4 U and 40.2 U, respectively; P = 0.50). No episode of severe hypoglycemia or clinically significant hyperglycemia with ketonemia occurred in either trial group. CONCLUSIONS Among inpatients with type 2 diabetes receiving noncritical care, the use of an automated, closed-loop insulin-delivery system resulted in significantly better glycemic control than conventional subcutaneous insulin therapy, without a higher risk of hypoglycemia. (Funded by Diabetes UK and others; ClinicalTrials.gov number, NCT01774565.)

Read the full article on the NEJM website: https://www.nejm.org/doi/full/10.1056/NEJMoa1805233805233

Recent Posts

  • Physiologic Insulin Resensitization as a Treatment Modality for Insulin Resistance Pathophysiology
  • Dynamic Diabetes Solutions: Physiologic Insulin Resensitization
  • Improved Kidney Function Following Physiologic Insulin Resensitization Treatment Modality
  • Reversal of Diabetic Neuropathy Utilizing Physiologic Insulin Resensitization
  • Closed-Loop Insulin Delivery for Glycemic Control in Noncritical Care

Recent Comments

  1. A WordPress Commenter on Pulsatile Insulin Secretion, Impaired Glucose Tolerance and Type 2 Diabetes

Patient & Visitor Guide

Plan your visit to our Clinic

More

Ever wondered what a Health Coach does?

Visit our Health Coach Demo!

Categories

  • Medical Articles

Archives

  • December 2022
  • October 2022
  • July 2021
  • August 2018
  • March 2018
  • November 2015
  • January 2015

Text Widget

Fugiat dapibus, tellus ac cursus commodo, mauesris condime ntum nibh, ut fermentum mas justo sitters amet risus. Cras mattis cosi sectetut amet fermens etrsaters tum aecenas faucib sadips amets.

Calendar

November 2026
M T W T F S S
 1
2345678
9101112131415
16171819202122
23242526272829
30  
« Dec    

Events & Workshops

no events found

Phoenix Clinic:

1-602-354-7474

intake@a1ctherapy.com

5040 North 15th Ave, Suite 107, 85015

Tucson Clinic:

520-624-0888

intake@a1ctherapy.com

1707 W. St. Mary's Rd, Suite 205, 85745

17 Locations in the Greater Phoenix Area, Call Us to Find the Nearest Location:
602-354-7474

Copyright A1CTherapy.com ©2026 all rights reserved.
A1C Therapy is a D/B/A of Pima Orthopedic Physicians, LLC est. 2007
Become a Provider

Get More Info